SOS: Lavry Engineering AD11 Bench test
Bench tests of the LavryBlack AD11 confirmed its impressive credentials, with the results matching or exceeding the published specifications. The dynamic range measured to the AES17 standard was 120dB, and THD+N was better than 0.001 percent for signals above -14dBFS in line mode (distortion rises rapidly above -4dBFS when the soft saturation mode is engaged, of course). The frequency response is ruler flat to 5Hz, and is roughly 30dB down at half the sample rate, achieving m